1、 Service Manual XTi Series RadioFans.CN 收音机爱 好者资料库 Table of Contents Section 1.Digital systems Overview 1.1.Amplifier Operation 1.2.Power Supply Operation 1.3.Tracker Supply Operation Section 2.Assembly Drawings 2.1.XTi1000 PWA BOM 139087-14 2.2.XTi1000 Schematic 139087-14 2.3.XTi2000 PWA BOM 139086
2、-14 2.4.XTi2000 Schematic 139086-14 2.5.XTi4000 PWA BOM 138349-14 2.6.XTi4000 Schematic 138349-14 Section 3.Firmware Notes Section 4.Tech Notes RadioFans.CN 收音机爱 好者资料库 CEquel Digital Systems Overview RadioFans.CN 收音机爱 好者资料库 CEquel Digital Systems Overview Page 2 of 16 CEquel Digital Systems Overview
3、 Page 3 of 16 Modes of Operation The CEquel microprocessor, LPC2142 can function in several different modes of operation. This document will describe what those modes are, how to get to them and how to use them. The Modes are listed below along with a brief description. Mode Name Description Normal
4、Normal Operating Mode, default Board Level Test Factory Only, part of functional test, (No line voltage present) Chassis Level Test (Self Test) Quick factory test (part of light zap) Chassis Diagnostic Test (Amp Indo Diagnostics) More detailed information about the current amp operation Bootloader M
5、ode Used to reprogram the microcontroller flash memory Front Panel Lockout Disables the front panel push buttons for security. Can be entered from front panel buttons or software. Normal Mode: This is the default mode of operation. The heartbeat LED (E1) should be beating at about 1Hz (500ms on, 500
6、ms off). Board Level Test Mode: Entered by pulling TP1 low at power up. Exit by pulling TP1 high. Operation Turn all front panel LEDs ON Turn all LCD segments ON Set the fan PWM to maximum Set the Soft_start relay OFF (assumes no line voltage is present). Only used by MFT Chassis Level Test Mode (Se
7、lf Test): Entered by powering up the unit with the PREV button pressed. Exit by successfully pressing all three buttons Operation Turn all front panel LEDs ON Turn all LCD icons ON and display “PRESS ME” Set the fan PWM to maximum Button Check Display which menu button is pressed. After exiting this
8、 mode, the main program should go get valid LM75 temperature readings and update the fan speed. If the amp is cool, it should turn the fan off CEquel Digital Systems Overview Page 4 of 16 Chassis Diagnostic Test Mode (Amp Info Diagnostics): NOTE: This mode is available to all users. Entered by press
9、ing all three front panel buttons for 3 seconds. Exit by successfully pressing SEL at any time. IMPORTANT!: When you are in the “AMP INFO” screens, the firmware is NOT running thru all of the normal routines. Clip check is called, but not as fast as normally, you will see more clipping. The thermal
10、limiter and fan should work just fine. The heartbeat LED and front panel LEDs will not update. The clip limiter and governor are also not running. Operation Display the present Power Supply measured temperature in degrees C Display the present Ch1 measured temperature in degrees C Display the presen
11、t Ch2 measured temperature in degrees C Display the present Firmware rev level (read from serial flash) Bootloader Mode: Entered by pulling TP17 low during power up. Exit by cycling the power. Operation Used to download new firmware to the LPC2142. It copies an internal boot-loader from flash to RAM
12、, where it executes. It erases the on-chip flash, and reprograms it. See the Programming document for more details. It is impossible to corrupt this boot-loader. It resides at a special location in internal Flash that is not accessible to anything. This should ALWAYS work! Front Panel Lockout: Enter
13、ed by holding UP and DOWN buttons down simultaneously. Exit by holding UP and DOWN buttons down simultaneously. Operation After holding down the up and down buttons for about 3 seconds, the LCD will display “LOCKED”, this indicates the amp is now in lockout mode. If any button is pressed, no action
14、will be taken, except to display the “LOCKED” message. IF you continue to hold the buttons down they will simply toggle the lockout mode on and off. Special Note: The front panel lockout mode can also be entered from the software. In this case, the software will supersede the front panel. So, holdin
15、g down the up and down buttons will NOT disable front panel lockout mode. When enabled from software, it can ONLY be disabled from software. This operation is consistent with the ITech. CEquel Digital Systems Overview Page 5 of 16 rmware CEquel Digital Systems Overview Page 6 of 16 CEquel Digital Sy
16、stems Overview Page 7 of 16 Updating Firmware RS-232 Method Part 1. If the microcontroller (U1, LPC2142) has NEVER been programmed before Connect the Serial 4-pin header to J2. IMPORTANT! The header MUST be connected with the correct polarity or fatal damage can result. Pin 1 on the header should be
17、 connected to pin 1 of the connector. See figure below: To program a new device connect the header to J2 and apply power. TP17 does NOT have to be pulled low because the micro does not have a valid program to run and will therefore automatically enter bootloader mode. Open up the Philips Flash Utili
18、ty Program (version 2.2.2) Under Flash Programming, make sure the correct file is selected to download. Select the Device (LPC2142), Select the XTAL Freq. (kHz): 16000 Select the Erase Entire Device button Select the correct file to load: (currently XTI_LPC_01_00_08b.hex) Press the Read Device ID bu
19、tton. The Part ID and Bootloader ID will show up. If they do not and this operation times out, then most likely, the device is not in bootloader mode, there is something wrong in the configuration or setup or the cable is not correctly connected. If the device is not in bootloader mode proceed to Pa
20、rt 2. Select Upload to Flash and the programming will start. After it is finished you may select Compare Flash. This will read back the flash memory and compare it to what was just programmed (Pass/Fail) Cycle the Power to the amp and close the Flash Utility Program. Xti Amp (back) (front) J2 : FRON
21、T Serial Interface board PC RS-232 CEquel Digital Systems Overview Page 8 of 16 Part 2. If the microcontroller (U1, LPC2142) has been previously programmed. To reprogram a device, it is first necessary to put it in bootloader mode. This is done by shorting TP17 to ground during a power up. After the
22、 unit powers up, the ground can be removed or left connected, doesnt matter. (Hint: Use a test lead connected to TP5(GND) on one end and TP17 on the other). The LCD should be blank. Again follow the steps in Part 1 to connect the Serial interface board to J2 and open the Philips Flash Utility. Press
23、 the Read Device ID button. The Part ID and Boot Loader ID should be displayed. Again follow the steps in Part 1 to send new firmware. If this does not work, there is most likely a hardware problem, check for shorts, correct power, bridges, other hardware problem. To verify serial flash and check th
24、e current firmware version number At any time hold down all three front panel buttons for at least 3 seconds. This puts the amplifier into a diagnostic mode. NOTE: While in this mode the front panel LEDs will NOT be updated. Also, the governor is disabled. Use the Next and Prev buttons to scroll thr
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Crown XTi_Series_Service_Manual_original 电路图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf