1、 Document type: Created: Page: SERVICE BULLETIN (2011-02-01) Page 1 of 8 THIS DOCUMENT IS CONFIDENTIAL. IT MAY NOT BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF LAB.GRUPPEN AB AND TC Electronic A/S 2005 Lab.gruppen AB, Faktorvgen 1, S-434 44 KUNGSBACKA, SWEDEN |. Technical Service Bulletin No. 21
2、Created by: Lab.gruppen AB Service Department Date: 2011-02-01 Reference no: CX models It is highly recommended to implement this service bulletin as preventative maintenance if the unit is serviced for another issue. Affected models Following models are affected by this technical service bulletin:
3、C20:8X, C10:8X, C10:4X & C5:4X Affected boards/modules Describe which boards/modules this technical issue affects. AICO4B08a-F01 or earlier. AICO4B08a-F02 or earlier. Symptom Amplifier may refuse to start up. If it starts up and there is no Audio on any channel. Solution AICO4B08x-FXX 1. Measure +18
4、V across C407 & - 18V across C405. 2. If +18V across C407 & - 18V across C405 is ok, then nothing is damage and follow service bulletin 21. 3. If zero, measure resistance between pin 2 & 3 at U403. If reading below 100 Ohm then U403 is broken and in need of replacement. 4. Measure resistance across
5、D422 and D423. If reading below 100 Ohm replace D422 & D423. AICO4B07x-Fxx or earlier. 1. Measure +18V across C407 & - 18V across C405. 2. If +18V across C407 & - 18V across C405 is ok, then nothing is damage and follow service bulletin 21. RadioFans.CN 收音机爱 好者资料库 Document type: Created: Page: SERVI
6、CE BULLETIN (2011-02-01) Page 2 of 8 THIS DOCUMENT IS CONFIDENTIAL. IT MAY NOT BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF LAB.GRUPPEN AB AND TC Electronic A/S 2005 Lab.gruppen AB, Faktorvgen 1, S-434 44 KUNGSBACKA, SWEDEN |. If zero, measure resistance between pin 2 & 3 at U403. If reading belo
7、w 100 Ohm then U403 is broken and in need of replacement. Measure resistance across C407 and C405 if below 100 Ohm then there are several damaged integrated circuits. Note! When service bulletin 10/14 is not implemented can U403 cause damage to several integrated circuits. AICO boards may need to be
8、 replaced. Contact Lab.gruppen for spare parts. Service Log Information Write “Technical Service Bulletin no.21” in column “Repair Remedy” besides other normal repair information. Instruction Part No. Description Amount Info Pos 1N4004 Diode Power 1n4004 1 See instruction 470n200VX7R 10%5 Capacitor
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- LabGruppen Service_Bulletin_2011_no_21_Unstable_18V_circuit 电路图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。
链接地址:http://www.radiofans.cn/p-215448.html



Marshall-9100-62-02-Schematic电路原理图.pdf