1、 2005-6 PRINTED IN JAPAN B53-0296-00 (N) 1703 CD RECEIVER KDC-MP928 KDC-PSW9531/PSW9531Y XXV-01D SERVICE MANUAL XXV-01D KDC-PSW9531/PSW9531Y K type E type K type E,M type K type E type KDC-MP928 SIZE AA BATTERY (Not supplied) Compact disc * (W01-1643-15) :K,M (W01-1647-05) :E Plastic cabinet assy (A
2、02-2749-03) Remote controller assy(RC-527) (A70-2067-05) Escutcheon (B07-3125-01) Mounting hardware assy (J21-9716-03) DC cord * (E30-6412-05) :E DC cord * (E30-6408-05) :K,M (E30-6414-05) :KDC-MP928 Lever (D10-4589-04) X2 Cleaning cloth * (W01-1649-05) Antenna adaptor * (T90-0523-05) Screw set * (N
3、99-1758-05) Screw (N09-6280-05) * Depends on the model. Refer to the parts list. CD MECHANISM EXTENSION CORD (24P) : W05-0934-00 A unique identification number (Unique ID) is given to each unit, which is imprinted on the CD mechanism assembly. If and when the mechanism assembly or Flash ROM (IC17) o
4、n the mechanism board is replaced, it is necessary to write the Unique ID. For details, refer to “How to Write the Unique ID” on Page 18. MODELTDF PANEL No.TDF NAME KDC-MP929Y33-2350-60 TDF-MP59D KDC-W9531/W9531YY33-2350-62 TDF-W9531 XXV-01D (K,M type)Y33-2350-61 TDF-XXV01DX XXV-01D (E type)Y33-2350
5、-63 TDF-XXV01D TDF PANEL INFORMATION This product uses Lead Free solder. RadioFans.CN 收音机爱 好者资料库 2 KDC-MP928/PSW9531 /PSW9531Y, XXV-01D BLOCK DIAGRAM F/E CD LX SW5V AM+B AGC RDS DECODER MEMO INSTALLER ROM CORR D3.3V A3.3V DRIVER MUTE LPFDAC D5V A5V A3.3V MUTE PRE SERGE PROTECTION OP AMP LEVEL SHIFT
6、DSP ADC IC301,302IC305IC303IC306-308 IC102 IC300 IC RESET P-CON ANT-CON DIMMER EXT AMP B.U DET SERGE DET ACC DET TEL MUTE SW 16V ILL+B A8V SW 14V BU5V PAN3.3V SW 16V OEL +B SERVO SW 5V (5VPRE) DC/DC MOTOR +B 5V PANEL MOTOR DRIVERMECHA PANEL OPEN/ PANEL DET 3.3V DRIVE COMP POWER IC DSI 3.3V 2.5V ROMC
7、OR E2P ROM SW (16x64kBIT) SRAMFLASHROM (16x8MBIT) OEL MODULE (256x64PIX. 4096COLOR) IR REMO CON ANA. SPE. (6BAND) BU5V A8V D5V SERVO BACK u-COM E-VOL u-COM (FST) BUS LPF IC400 IC104 IC4 IC750 CD D5V A8V A8V SW5V UP BU5V A8V BU5V REF SVR BU5V D3.3V BU5V A8V 9V CLOSE SW5V SERVO SW SWSWSWSWSW SW SW LEV
8、EL SHIFT 9V D5V SHIFT LEVEL IC RESET AUX IN PRE OUT(REAR) SP OUT(FR) OPEL DISP P CON ANT CON EXT. AMP. CON DIMMER LINE ACC BACK UP KEYS RESET JOG ROTARY BU5V PRE OUT(FRONT) PRE OUT(SW) SP OUT(FL) SP OUT(RL) SP OUT(RR) WIRED REMO ILL+B E2P ROM FST AUX FM/AM CD CH SPE ANA MPX for RDS MUTE 0,1,2 WININ
9、DCERR MUTE A,C MUTE A,C RST STBY OFFSET MUTE 0,1,2 PRE MUTE RST E2P P-ON ROM P-ON I2C BUS RESET A1-A23 D0-D15 GREEN KEY ILL KEY ILL RED SUB ILL BLUE(R) SUB ILL BLUE(L) TRIANGLE ILL CONT. KEY SCAN KEY IN P-ON 5V A/D 7CH CW. CCW SPE ANA 5V SYSTEM 3.3V SYSTEM PANEL ELECTRIC UNIT (X34-356) RadioFans.CN
10、收音机爱 好者资料库 3 KDC-MP928/PSW9531 /PSW9531Y, XXV-01D BLOCK DIAGRAM TR COIL FO COIL C F AB E PD LD SERVO DSP MOTOR DRIVER SP MOTOR LOADING by long-pressing for 2 seconds, all error log information is cleared. (Display) I2C_ (Display) ERR_1-, 2-, 3- In “”, “OK” or “NG” is displayed. In “”, “ ” or an erro
11、r code is displayed. (*1) One count is made when the panel opens to full or when a disc is loaded. CE DATA CLK 500msec 500msec 500msec G sensor display items When source is STANDBY, by short-pressing ATT key, the display is switched to analogy meter display, in which verti- cal G and horizontal G ar
12、e displayed. Special display when all lights are on When all lights are on with the STANDBY source, the fol- lowing displays are made when the keys shown below are pressed. 16 KDC-MP928/PSW9531 /PSW9531Y, XXV-01D TEST MODE Initializing AUDIO-related value setting During STANDBY sourcing, by short-pr
13、essing key, AU- DIO setting values are returned to the default values. Flash ROM/Static RAM check 1. When entering the test mode, the manufacture code of the Flash ROM (16M) is read and when it is normal, FROMCHK terminal of the 100pin repeats HiLowHi . If the read- ing is abnormal, “Low” is output.
14、 If the manufacture code is normal, by short-pressing key, the connection checks on all terminal is started. If the connections are normal, the FROMCHK terminal stops the HiLowHi repeating and outputs “Hi.” If the reading is abnormal, “Low” is output. 2. With all lights turned on and by long-pressin
15、g AM key, the data on the Flash ROM (16M) is initialized. While erasing the data, “Data_Erase. . . .” is displayed. Note : Do not touch any key white this is in progress. When erasing is complete, “Erase_OK!” is displayed. If “Erase_NG!” is displayed, it was not possible to erase the data on the Fla
16、sh ROM (16M). In this case, long-pressing AM key again. If it is the same, then there is an abnormality with the Flash ROM. 3. Regardless of the state of the test mode, when the power is turned on, the manufacture code on the Static RAM is read and, when, normal, Hi is output by the SRAMCHK terminal
17、. When abnormal, Low is output. Other At Power ON “CODE_OFF”, “CODE_ON” displays will not be made. When sourcing STANDBY, by short-pressing AUTO / TI key, GREEN/RED of the key illumination is switched. When staring up in the test mode, LINE MUTE prohibition time is set to 1 second instead of 10 seco
18、nds. While in the test mode, security jig should not be used to write the security code. While in the test mode, serial writing jig should not be used to write the serial number. While in the test mode, even when a DC error is detected, the detection information will not be written to the E2PROM. Wh
19、ile in the test mode, even after an elapse of pre-set time, the backup memory items will not be written to the E2PROM. Information Clear mode for Test Mode, backup/installer memory, and CD mechanism error log. In the DC error de- tection information clear mode, DEMO mode operation will not be conduc
20、ted. Also, in the above mode, the menu of the STANDBY source will not display DEMO ON/OFF switching items. While in the test mode, and at the same time, PM_DET terminal is H, the following will apply to the EJECT key, regardless of whether a disc is in the unit or not. Panel full OPEN/CLOSE is condu
21、cted with a short-push. (Protection time: 3 seconds) As far as this item is concerned, eject will be achieved by 1 second long-push on the EJECT key. Clearing backup memory and installer memory data (Clearing E2PROM data) 1. By pressing NEXT key and ATT key simultaneously, re- set and start the unit
22、. This will start the initialization pro- cesses for backup and installer memory data and the error log information of the CD mechanism. 2. When initialization is complete, the following display will be made. Normal completion Abnormal ending 1 backup/installer memory initialization: NG Abnormal end
23、ing 2 CD mechanism error log initialization: NG Abnormal ending 3 All initialization: NG 3. While in this mode, even after an elapse of a pre-set time, no backup memory items will be written to the E2PROM. 4. This mode is released by resetting. (What was on the last screen will not be retained.) CD_
24、E2P_ : AUDIO_E2P : CD_E2P_ : AUDIO_E2P : CD_E2P_ : AUDIO_E2P : CD_E2P_ : AUDIO_E2P : 17 KDC-MP928/PSW9531 /PSW9531Y, XXV-01D TEST MODE Clearing DC error detection information (E2PROM data clear) 1. By resetting, while pressing both ATT key and AUD key simultaneously, enter the DC error display mode.