Thomson-RS2625-cs-sm 电路图 维修手册.pdf
《Thomson-RS2625-cs-sm 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Thomson-RS2625-cs-sm 电路图 维修手册.pdf(63页珍藏版)》请在收音机爱好者资料库上搜索。
1、SAFETY PRECAUTIONS Page 1-2 DO NOT OPERATE THIS INSTRUMENT OR PERMIT IT TO BE OPER- ATED WITHOUT ALL PROTECTIVE DEVICES INSTALLED AND FUNCTIONING. SERVICERS WHO DEFEAT SAFETY FEATURES OR FAIL TO PERFORM SAFETY CHECKS MAY BE LIABLE FOR ANY RESULTING DAMAGE, AND MAY EXPOSE THEMSELVES AND OTH- ERS TO P
2、OSSIBLE INJURY. READ AND COMPLY WITH ALL CAUTION AND SAFETY-RELATED NOTES ON OR INSIDE THE RECEIVER CABINET, AND THE RE- CEIVER CHASSIS, OR ON THE PICTURE TUBE. SAFETY GLASSES SHOULD BE USED WHEN SERVICING ELEC- TRONIC INSTRUMENTS. INADVERTENTLY OVERSTRESSING COM- PONENTS MAY CAUSE THEM TO SHATTER,
3、DISCHARGING SMALL PARTICLES. DESIGN ALTERATION WARNING - Do not alter or add to the mechanical or electrical design of this instrument. Design alterations and additions may alter the safety characteristics of this instrument and create a hazard to the user. Design alterations or additions may void t
4、he manufacturers warranty and may make you, the servicer, responsible for personal injury or property damage resulting there- from. BEFORE RETURNING AN INSTRUMENT TO THE CUSTOMER, always make a safety check of the entire instrument, including, but not limited to, the following items: FIRE AND SHOCK
5、HAZARD 1. Never release a repaired unit unless all protective devices such as insula- tors, barriers, covers, strain reliefs and other protective hardware have been installed in accordance with the original design. 2. Be sure that there are no cabinet openings through which an adult or a child might
6、 be able to insert their fingers and contact a hazardous voltage. Such openings include, but are not limited to: (a) spacing between picture tube and cabinet mask, (b) excessively wide cabinet ventilation slots, and (c) an improperly fitted or incorrectly secured back cover or cabinet. 3. Observe or
7、iginal lead dress. Take care to restore leads to their original dress. Make sure that leads are not in contact with sharp edges or thermally hot parts. Always inspect in all areas for pinched, out-of-place or frayed wiring. Do not change spacing between adjacent components, or between components and
8、 printed circuit board. Check the AC power cord for dam- age. 4. Be certain to remove loose solder balls and all other loose foreign particles. 5. Check components, parts and/or wiring for physical evidence of damage, overheating or deterioration, and replace if necessary. Determine the cause of dam
9、age and/or overheating and, if necessary, take corrective action to remove any potential safety hazard. 6. Parts Replacement - Many instruments electrical and mechanical parts have special safety-related characteristics, some of which are often not evident from visual inspection, and the protection
10、they give cannot necessarily be obtained by replacing them with components rated for higher voltage, watt- age, etc. Parts that have special safety characteristics are identified in this service data by a ( ) on schematics and in the parts list. Use of a substitute replacement that does not have the
11、 same safety characteristics as the recom- mended replacement part in the service data parts list may create shock, fire and/or other hazards. Always consult the appropriate current service litera- ture for the latest information. 7. Some instruments chassis normally have 85VAC (RMS) between chassis
12、 and earth ground, regardless of the AC plug polarity. Some instrument chassis are electrically connected directly to one conductor of the AC power cord. Some instrument chassis have a secondary ground system in addition to the main chassis ground. This secondary ground system is not isolated from t
13、he AC power line. The two ground systems are electrically separated by insulating material that must not be defeated or altered. Thus, when servicing any unit always use a separate isolation transformer for the chas- sis. Failure to use a separate isolation transformer may expose the servicer to pos
14、sible shock hazard, and may cause damage to servicing instruments. 8. Many electronic products use a polarized AC line cord (one wide pin on the plug). Defeating this safety feature may create a potential hazard to the servicer and the user. Extension cords that do not incorporate the polarizing fea
15、ture should never be used. PICTURE TUBE IMPLOSION WARNING - If the instrument being serviced incorperates a picture tube it will employs integral implosion protection. For continued implosion protection, replace the picture tube only with one of the same type number. Do not remove, install, or other
16、wise handle the picture tube in any manner with- out first putting on shatterproof goggles equipped with side shields. People not so equipped must be kept safely away while picture tubes are handled. Keep the picture tube away from your body. Do not handle the picture tube by its neck. Some “in-line
17、” picture tubes are equipped with a permanently attached deflection yoke; because of potential hazard, do not try to remove such “permanently at- tached” yokes from the picture tube. X-RADIATION AND HIGH VOLTAGE LIMITS - Because the picture tube is the primary source of X-radiation in solid-state TV
18、 receivers, it is specially constructed to prohibit X-radiation emissions. For continued X-radiation protec- tion, a replacement picture tube must be the same type as the original. The picture shields, mounting hardware and lenses (projection TV) may also perform an X- radiation protection function,
19、 and they must be correctly in place. Anode connec- tors contain an X-radiation shield - use only the manufacturers specified anode connectors. High voltage must be measured each time servicing that involves power supply, horizontal deflection or high voltage circuits is performed. Correct operation
20、 of the X-radiation circuits must also be confirmed each time these cir- cuits are serviced (X-radiation circuits may also be called “horizontal disable” or “hold-down” circuits). Read and apply high voltage limits and, if the chassis is so equipped, the X-radiation protection circuit specifications
21、. These limits and speci- fications are given on instrument labels and are included in this service data. High voltage is maintained within specified limits by close-tolerance safety-related com- ponents (and adjustments) in the high voltage circuit. If high voltage exceeds specified limits, check e
22、ach safety related component specified on the schematic and take corrective action. ANTENNA LEAKAGE RESISTANCE CHECK - With the instrument AC plug removed from the AC source, connect an electrical jumper across the two AC plug prongs. Place the instrument AC switch (if applicable) in the “on” positi
23、on. Connect one lead of an ohmmeter to the AC plug prongs and touch the other ohmmeter lead, in turn, to each (exposed) antenna input terminal screw and/or coaxial connector. If the measured resistance is less than 1.0 Megohm, or greater than 5.2 Megohm, an abnormality exists which must be corrected
24、 before the in- strument is returned to the customer. Repeat this test with the AC switch in the “off” position. LEAKAGE CURRENT HOT CHECK FOR 2-WIRE OR 3-WIRE GROUNDED CORD SETS - With the instrument completely reassembled, plug the AC line cord into the mains AC outlet at normal line voltage via a